Tech Serve Solutions

o-Eugenol

CAS 579-60-2H2C=CHCH2C6H3(OCH3)OHChemical Synthesis

o-Eugenol (CAS 579-60-2), with the linear formula H₂C=CHCH₂C₆H₃(OCH₃)OH and a molecular weight of 164.20 g/mol, is a phenolic organic compound. This chemical serves as a versatile building block in organic synthesis. Its characteristic structure allows for various chemical transformations, making it valuable in the development of more complex molecules for research and industrial applications.

IUPAC
2-Allyl-6-methoxyphenol
Synonyms
2-Allyl-6-methoxyphenol6-Methoxy-2-allylphenol
Email us
o-Eugenol (H2C=CHCH2C6H3(OCH3)OH) — chemical structure, CAS 579-60-2; Chemistry, fine chemical supplied by Tech Serve Solutions
Building BlocksC9 to C20+Chemical SynthesisOrganic Building BlocksOxygen CompoundsPhenols More...
01 /Applications

Organic Synthesis Intermediate

o-Eugenol functions as a key intermediate in the synthesis of diverse organic compounds. Its allyl and phenolic functionalities enable a range of chemical reactions for constructing complex molecular architectures.

Research and Development

This compound is utilised in laboratory settings for research purposes, particularly in exploring new synthetic pathways and developing novel materials or chemical entities.

Building Block for Fine Chemicals

As an organic building block, o-Eugenol is employed in the creation of various fine chemicals, contributing to advancements in chemical manufacturing and product development.

02 /Properties
Molecular weight164.20
Linear formulaH2C=CHCH2C6H3(OCH3)OH
Assay98%
Boiling point119-121 °C/12 mmHg(lit.)
Density1.068 g/mL at 25 °C(lit.)
Refractive indexn20/D 1.538(lit.)
03 /Safety & handling
GHS hazard pictogram: Harmful / irritant (GHS07)
Harmful / irritant
GHS hazard pictogram: Health hazard (GHS08)
Health hazard
Danger

Hazard statements

  • H315Causes skin irritation
  • H317May cause an allergic skin reaction
  • H319Causes serious eye irritation
  • H334May cause allergy or asthma symptoms if inhaled
  • H335May cause respiratory irritation

Precautionary statements

  • P261Avoid breathing dust, fume, gas or vapours
  • P280Wear protective gloves, clothing and eye/face protection
  • P305IF IN EYES
  • P342
Protective equipmentEyeshields, Faceshields, full-face respirator (US), Gloves, multi-purpose combination respirator cartridge (US), type ABEK (EN14387) respirator filter
Flash point113 °C / 235.4 °F
Water hazard class (WGK, DE)3
Hazard codes (EU)Xn
Risk statements (R)36/37/38-42/43
Safety statements (S)23-26-36

Hazard information is provided for guidance. Always consult the product Safety Data Sheet (SDS), available on request, before handling.

04 /Identifiers & registry
CAS number
579-60-2
MDL number
MFCD00192169
PubChem substance
24864347
05 /Quality & supply

Documentation

Every batch ships with a Certificate of Analysis covering assay, identity and purity; the grade is confirmed against your enquiry. Safety Data Sheets and technical data sheets are available on request.

Supply & logistics

Samples for technical evaluation; bulk MOQ by grade and packaging. In-stock material ships in 7–10 working days, worldwide, with full export documentation.

06 /Frequently asked questions

What is o-Eugenol used for?

+

o-Eugenol is primarily used as a building block and intermediate in organic synthesis and for research and development purposes in chemical laboratories.

What is the CAS number and chemical formula for o-Eugenol?

+

The CAS number for o-Eugenol is 579-60-2, and its linear formula is H₂C=CHCH₂C₆H₃(OCH₃)OH.

What grade and purity does Tech Serve Solutions supply?

+

Tech Serve Solutions supplies o-Eugenol with an assay of 98%. This product is supplied for laboratory and research use. TSS does not represent this product as USP, BP, EP, or other pharmacopoeial grades.

How should o-Eugenol be handled safely?

+

o-Eugenol is classified with GHS07 and GHS08 symbols and carries a Danger signal word. It is associated with hazards H315 (causes skin irritation), H317 (may cause an allergic skin reaction), H319 (causes serious eye irritation), H334 (may cause allergy or asthma symptoms or breathing difficulties if inhaled), and H335 (may cause respiratory irritation). Appropriate personal protective equipment, including eyeshields, gloves, and suitable respiratory protection, must be used. Handle in a well-ventilated area.

Is o-Eugenol a controlled substance?

+

The provided data does not indicate that o-Eugenol is a controlled substance.

How is o-Eugenol packed, shipped, and exported?

+

o-Eugenol is carefully packed to ensure integrity during transit. As a global supplier, Tech Serve Solutions exports chemicals worldwide, adhering to international shipping regulations for hazardous materials.

How can I request a sample or quote for o-Eugenol?

+

To request a sample or a quote for o-Eugenol, please contact the Tech Serve Solutions sales department through the provided contact information on our website.

Need o-Eugenol in a specific grade or volume?